Homeowner’s
Installation and
Operating Manual
For use in Europe
Do Not Discard This Manual: Retain for Future Use
30003846 4/08 Rev. 1
SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND
MAINTAINED, A HOUSE FIRE MAY RESULT.
TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. FAILURE TO
FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN
DEATH. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION
INSPECTION REQUIREMENTS IN YOUR AREA.
0968
Defiant cover
11/00
Defiant
Non-Catalytic
Woodburning Stove
Model 1610CE
Zobrazit stránku 0
1 2 3 4 5 6 ... 27 28

Shrnutí obsahu

Strany 1 - Woodburning Stove

Homeowner’s Installation and Operating ManualFor use in EuropeDo Not Discard This Manual: Retain for Future Use30003846 4/08 Rev. 1SAFETY NOTICE:

Strany 2 - All of Us at CFM Corporation

10Defiant 1610CE Non-Catalytic Woodburning Stove30003846Costructional Hearth Dimensions as belowAt least 300 mm At least 150 mm or to a suitable heat

Strany 3 - The Story of the Defiant

11Defiant 1610CE Non-Catalytic Woodburning Stove30003846Summary of ClearancesMinimum recommended side clearances to non-combustible surfaces 125 mm (5

Strany 4 - Defiant, Model 1610CE

12Defiant 1610CE Non-Catalytic Woodburning Stove30003846Set Up Your StoveCast iron stoves are heavy, and it will take two to four people to move your

Strany 5 - Installation

13Defiant 1610CE Non-Catalytic Woodburning Stove30003846Install the Optional Ash Door Heat ShieldMany installations will require the use of the suppli

Strany 6 - 12/13/99 djt

14Defiant 1610CE Non-Catalytic Woodburning Stove30003846The Defiant Controls Two controls regulate the performance of the Defiant: a primary air contro

Strany 7 - Chimney connector

15Defiant 1610CE Non-Catalytic Woodburning Stove30003846DefiantST521Intrepidloading11/00ST521Fig. 28 Top loading is the best way to add fuel during r

Strany 8

16Defiant 1610CE Non-Catalytic Woodburning Stove30003846agement information on Page 26 to see how the size, type, and location of your chimney will af

Strany 9 - Wall Pass-Throughs

17Defiant 1610CE Non-Catalytic Woodburning Stove30003846ST263starting a fire12/99ST263Fig. 31 Start the fire with newspaper and dry kindling.ST264g

Strany 10 - Clearances

18Defiant 1610CE Non-Catalytic Woodburning Stove30003846operating temperature quickly. Use this sequence as a guide to successful refueling:NOTE: Doo

Strany 11 - Fig. 11 Minimum clearances

19Defiant 1610CE Non-Catalytic Woodburning Stove30003846Draft ManagementA stove is part of a system, which includes the chimney, the operator, the fu

Strany 12 - Assembly

2Defiant 1610CE Non-Catalytic Woodburning Stove30003846This manual describes the installation, operation, and maintenance of the Vermont Castings Defia

Strany 13 - 

20Defiant 1610CE Non-Catalytic Woodburning Stove30003846they must turn, it leaves some pipe in the room for heat transfer, and it gives you long-term

Strany 14 - Operation

21Defiant 1610CE Non-Catalytic Woodburning Stove30003846Below you will find important information on general care, inspection and maintenance of your V

Strany 15 - Intrepid

22Defiant 1610CE Non-Catalytic Woodburning Stove30003846Adjust the Damper as NeededThe tension on the Defiant’s damper is adjustable to compensate for

Strany 16

23Defiant 1610CE Non-Catalytic Woodburning Stove300038463. Determine the correct length of the appropriate-sized gasket by laying it out in the channe

Strany 17

24Defiant 1610CE Non-Catalytic Woodburning Stove30003846Clean the chimney connector by disconnecting the sec-tions, taking them outside, and removing

Strany 18 - • Open the damper

25Defiant 1610CE Non-Catalytic Woodburning Stove300038461287242320221921131451617182569643565678393288424350411548384034253545558767570746880786777757

Strany 19 - Draft Management

26Defiant 1610CE Non-Catalytic Woodburning Stove30003846Defiant Woodburning Stove Model 1610CE (continued) 1. Side Insulation 30002846 2. Right Si

Strany 20

27Defiant 1610CE Non-Catalytic Woodburning Stove30003846Defiant Woodburning Stove Model 1610CE (continued) Shell Enamel Parts - Defiant Model 1610CE

Strany 21 - Maintenance

LIMITED LIFETIME Warranty For Vermont Castings Defiant, Non-Catalytic Wood StoveLimited Lifetime WarrantyCFM Corporation warrants that all refractory

Strany 22 - Damper adjustment

3Defiant 1610CE Non-Catalytic Woodburning Stove30003846Table of ContentsSpecifications ... 4Installation

Strany 23 - The Chimney System

4Defiant 1610CE Non-Catalytic Woodburning Stove30003846SpecificationsDefiant, Model 1610CENominal heat output ...14.5 kW (49,500 BTU/hr)1Mnimu

Strany 24 - Ash Build-up

5Defiant 1610CE Non-Catalytic Woodburning Stove30003846InstallationSAFETY NOTICE: IF YOUR DEFIANT IS NOT PROP-ERLY INSTALLED, A HOUSE FIRE MAY RESUL

Strany 25 - Model 1610CE

6Defiant 1610CE Non-Catalytic Woodburning Stove30003846What Kind of Chimney to UseYou must connect the Defiant to a code-approved masonry chimney with

Strany 26 - Model 1610CE (continued)

7Defiant 1610CE Non-Catalytic Woodburning Stove30003846c) Mild steel fluepipes complying with BS 1449: Part 1: 1991, with a flue wall thickness of at le

Strany 27

8Defiant 1610CE Non-Catalytic Woodburning Stove30003846securely in place. Most chimney breeches incorporate thimbles, but the fit must be snug and the

Strany 28 - LIMITED LIFETIME Warranty

9Defiant 1610CE Non-Catalytic Woodburning Stove30003846Through the FireplaceIf your fireplace opening height is at least 737 mm (29"), you may ins